Dynaspede Integrated Systems
  Dynaspede Home Products Services Corporate Info Careers Contact Dynaspede Sitemap  
 
    Blown Film Treating Systems
 

Enercon Corona Treating Systems

Enercon Blown Film Treating System meets application needs at Low Cost.

The Enercon Blown Film Treater is the culmination of a quarter century of application experience in meeting the specific requirements for surface treatment on blown film extruders. This compact, simple construction that allows 2-side treating and adjustable lane treating meets all the basic application needs. Add to that a station that is visually open, easy to thread and an electrode system that provides simple, trouble-free air-gap adjustment. Finally, compare the price of this system with any other. Now you have the ultimate in Blown Film Treating!
 
 
Blown Film Station with Optional High Voltage Transformer Bracket Mounted.  

Blown Film Treating Station Showing Electrode Retraction Levers and Ozone Exhaust Flange.

 

Standard Features & Benefits

Overall Station Dimensions:

 
Station Depth Height Width
with Mounted XFMR: 20”(508 mm) 15”(381 mm) 43.25”(1099 mm) + Treat Width
without XFMR: 20”(508 mm) 15”(381 mm) 23.5”(597 mm) + Treat Width
       

Standard Treat Widths

(TW): 42”(1067 mm), 52”(1321 mm), 62”(1575 mm), 72”(1829 mm)

Electrode Assembly

  • 1/8” (3 mm) Aluminium, Flip-type segments, Special Design*, Custom-manufactured
  • 1.25” (32 mm) Electrode width (determines Electrode Area and Dwell Time)
  • Electrode air gap adjustable from outside the Station
  • Manual Lever and Lock Mechanism for Retraction of each Assembly
  • Two-side Treatment - One Electrode Assembly per Side
  • High Voltage Transformer (XFMR) with 10’ (3 meters) of HV wire
Electrode segments in and out of treat position to allow lane treatment.

 

Treater (Ground) Roll

  • 3.9” (100 mm) Diameter, Steel, Dead Shaft mounted on Free-Running Bearings
  • Silicone Sleeve Dielectric

Frame Construction

  • Aluminum End Plates
  • Aluminum Extrusion Tie-Bars
  • Bolted Frame
  • Aluminum Ozone Exhaust Flange

Safety

  • Lexan Station Covers – Provide Complete Visibility and hinge for easy threading
  • Magnetic Safety Switches on hinged station covers
  • G-10 Insulator isolating the Retraction Handle from Electrode
  • Ozone Exhaust Flange on opposite end from high voltage connections
  • Zero speed Sensor – shuts down Power Supply when the line stops
  • NEMA 1 Low Voltage Terminal Box for Speed Sensor and Interlock Connections
Port provided in end plate permits viewing of electrode air-gap during operation.
 

Treater Station Options

  • Pneumatically Actuated Electrode Retraction
  • Electronic Airflow Switch mounted in the Station Exhaust Duct
  • Ceramic or Epoxy Covered (Ground) Treater Roll
  • Bracket for mounting high voltage Transformer (XFMR) to Station
  • Stainless Steel Segments

Power Supply Features

  • 7 Ratings: 1, 2, & 3 kW in a 17” (432 mm) H x 14” (356 mm) W x 12” (305) D Enclosure**
  • 4, 5, 7.5 & 10 kW in a 22” (546 mm) H x 14” (362 mm) W x 13” (337 mm) D Enclosure**
  • Flip-Open NEMA 1 Enclosure
  • Latest State-of-the-Art Control and Power Circuits and Components
  • Membrane Panel Control and Indication: Digital Readout of output kW
  • Easy Setup & Operation
  • Self-Checks All Interlocks for Safe Start-up
  • Retains Set-point in Non-Volatile Memory

Power Supply Options

  • Remote Control
  • “Chassis Only” for Mounting in Customer’s Enclosure
 
Corona Blown Film
 
 
 
© 2007. All rights reserved. An ISO 9001:2000 Certified Company Developed by Macrocomm Media